IM4 pitch alignment in and out of lock, O3

While watching H1 relock I can see IM4 alignment chaging by around 60urad, so I searched O3, and see that in April the dirrefence was around 15urad, then in early May that drops to 5-6urad, then it's about 10urad, and by May 9th it's about 40urad.  It continues to change periodically, though remains at 40+urad, and currently the change is 60urad.  What's interesting is that the big change does not cooincide with the increase in power to 37W.   Plot shows IMC_IN and IM4 pitch, 150 days.  Chart shows changes every month, O3.

Images attached to this report
Comments related to this report
cheryl.vorvick@LIGO.ORG - 17:18, Monday 02 September 2019 (51679)

two additional plots showing IM4 Yaw:

  • plot 1 shows IM4 pitch and yaw and ISC_LOCK_STATE_N as H1 goes from unlocked to NLN. 
    • upper left plot is IM4 yaw, and the ISC_LOCK_STATE_N is in the 400's, IM4 yaw is moved almost 30urad, and then back again
    • at the same time, IM4 pitch move more than 60urad
  • plot 2 shows 150 days, the same time fram as the original post's attached plot
    • this plot has both IM4 pitch and yaw
    • upper plot is yaw, and toward the right side og the plot, one can see that IM4 yaw is now routinely traveling around 25urads, and then back, during lock aquisition
    • this change coincides with IM4 pitch increasing it's motion during relocking from around 40urad to 60urad
Images attached to this comment