01:51UTC EX and H_T_T_S Verbal Alarms. Nothing environmentally obvious
02:31 unable to cover PRMI in a timely manner
2:32 IA
2:55 Re-Lock attempt - 1
- Vetoed DRMI for PRMI - optimized by hand a bit and let ASC take it
- DRMI locked in about a minute
- failed at ENGAGE_SOFT_LOOPS
- I haven't yet tried re-loading the ISC_DRMI node as Sheila stated in her aLog
03:16 Re-Lock attempt -2
- lost it a minute into ENGAGE_SOFT_LOOPS
- I waited and watched ASC signals at ENGAGE_ASC_FOR_....
- going to implement the ISC_DRMI code reload
03:39 Loaded new ISC_DRMI code
03:40 Re-Lock attempt - 3
- 13 minutes into ENGAGE_SOFT_LOOPS and lockloss, again
04:09 Re-Lock attempt - 4
- Lockloss at ACQUIRE_DRMI_1F
~ 4:30UTC I placed a call to Sheila
- Sheila was on phone support until 5:8UTC
- We decided to turn the sensor correction at EX off based on aLog 51338
5:20UTC NLN
- Accepted SR2 and SRM SDF diffs - forgot to ss the SRM.
- the diff for SRM was F1,F5 for M1_LOCK
5:24UTC Observing