Reports until 12:41, Tuesday 03 September 2019
H1 CAL (CAL)
madeline.wade@LIGO.ORG - posted 12:41, Tuesday 03 September 2019 (51711)
GDS calibration pipeline restart with complex kappa correction turned off

[J. Betzwieser, T. Mistry, M. Wade, A. Viets]

As per LHO alog 51654, we have decided to adjust the configuration for the GDS calibration pipeline to *not* correct for the complex actuation time-dependent correction factors.  Instead, we will only correct for the real part of the actuation time-dependent correction factors.  I have made this configuration change in the GDS calibration pipeline.  The new configuration file is in the calibration SVN

aligocalibration/trunk/Runs/O3/GDSFilters/H1GDS_1251572901.ini

The primary and redundant calibration pipelines were restarted with these configurations around GPS time 1251572901.