Reports until 17:45, Wednesday 04 September 2019
H1 CAL (DetChar, ISC, OpsInfo)
jeffrey.kissel@LIGO.ORG - posted 17:45, Wednesday 04 September 2019 (51738)
Calibration Measurements: Full Suite Today, both in Nominal Config and Proposed Improved Actuator Config
M. Ball, S. Dwyer, J. Kissel

We were able to collect the entire suite of calibration measurements (sensing function suite and each of the three actuation stage suites) in 
    - the current nominal configuration (i.e. Spot moved back to "July" positions, with a digitally requested SRCL offset; see LHO aLOGs 51592 and 51440), and 
    - in the proposed new actuator configuration (i.e. PUM L2A filters back on, and with the UIM longitudinal control boosted below 0.3 Hz; see 51717 and 51709).

Recall that we plan to update the front-end calibration next week Monday (Sep 9 2019), and in doing so, adopt the newest, latest, bestest configuration tested today and thus create a new epoch of O3. 
These measurements will inform and complement that model and its uncertainty nicely. 
Also, FYI, that update will resolve the discrepancy between front-end and GDS computed BNS ranges on the summary pages (not the reason we're doing it, but a nice side benefit).

Analysis and more details to come!

Here're the data:
Sensing Function measurements:
/ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/O3/H1/Measurements/FullIFOSensingTFs/
Nominal Config:
    2019-09-04_H1_PCALY2DARMTF_BB_3min.xml    | Newly tuned excitation to better facilitate studies like LHO aLOG 51654
    2019-09-04_H1_NominalConfig_DARM_OLGTF_LF_SS_5to1100Hz_15min.xml
    2019-09-04_H1_NominalConfig_PCALY2DARMTF_LF_SS_5t1100Hz_10min.xml

    2019-09-04_H1_L2ADecoupUIMBoost_DARM_OLGTF_LF_SS_5to1100Hz_15min.xml    
    2019-09-04_H1_L2ADecoupUIMBoost_PCALY2DARMTF_LF_SS_5t1100Hz_10min.xml

Actuator Measurements:
/ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/O3/H1/Measurements/FullIFOActuationTFs/
Nominal Config:
    2019-09-04_H1SUSETMX_L1_iEXC2DARM_10min.xml
    2019-09-04_H1SUSETMX_L1_PCAL2DARM_8min.xml
    2019-09-04_H1SUSETMX_L2_iEXC2DARM_12min.xml
    2019-09-04_H1SUSETMX_L2_PCAL2DARM_6min.xml
    2019-09-04_H1SUSETMX_L3_iEXC2DARM_12min.xml
    2019-09-04_H1SUSETMX_L3_PCAL2DARM_6min.xml

With proposed PUM L2A decoupling ON and UIM Boost ON
    2019-09-04_L2ADecoupUIMBoost_H1SUSETMX_L1_iEXC2DARM_12min.xml
    2019-09-04_L2ADecoupUIMBoost_H1SUSETMX_L1_PCAL2DARM_8min.xml
    2019-09-04_L2ADecoupUIMBoost_H1SUSETMX_L2_iEXC2DARM_12min.xml
    2019-09-04_L2ADecoupUIMBoost_H1SUSETMX_L2_PCAL2DARM_6min.xml
    2019-09-04_L2ADecoupUIMBoost_H1SUSETMX_L3_iEXC2DARM_12min.xml
    2019-09-04_L2ADecoupUIMBoost_H1SUSETMX_L3_PCAL2DARM_6min.xml