Displaying report 1-1 of 1.
Reports until 11:46, Thursday 05 September 2019
H1 CDS
david.barker@LIGO.ORG - posted 11:46, Thursday 05 September 2019 (51756)
update on nuc5 investigation

Jonathan, Carlos, Dave:

I've posted details in the FRS. I was able to see a segfault on one of the dmtviewers during testing this morning.

History:

Tue 3rd Sep 2019: maintenance, nuc5 upgraded from deb8 to deb9 (Carlos), launch.sh script modified to auto start dmtviewer and diaggui (Dave)

Tue 3rd Sep 2019: evening, Ed sees the FOM_STS dmtviewer crash.

Thu 5th Sep 2019: early hours, Travis sees the FOM_3-30Hz crash twice within hours

Thur 5th Sep 2019: Dave sees FOM_STS crash (segfault reported)

Carlos has been testing a dmtviewer (IFO range) on a new Nuc machine running a clean deb9 install in his office with no problems.

So, PLAN A is to upgrade nuc5 from its current old hardware with an upgraded deb9 to a new nuc with a clean deb9 install.

In the mean time, if a dmtviewer crashes, the easy way to restart it without having to reboot nuc5:

Get remote access to nuc5

    xvncviewer nuc5

Open a terminal on the Desktop, and type

    pkill dmtviewer

    pkill diaggui

    /home/controls/startup/launch.sh

Displaying report 1-1 of 1.