Displaying report 1-1 of 1.
Reports until 15:30, Monday 09 September 2019
H1 PSL
edmond.merilh@LIGO.ORG - posted 15:30, Monday 09 September 2019 (51829)
PSL Weekly Status FAMIS #11029

 Laser Status:
    Front End Power is 32.01W (should be around 30 W)
    70W Output Power is 69.7W
    Front End Watch is GREEN
    70W Watch is GREEN

    PMC:
    It has been locked 11 days, 3 hr 37 minutes (should be days/weeks)
    Reflected power = 10.65Watts
    Transmitted power = 52.96Watts
    PowerSum = 63.6Watts.

    FSS:
    It has been locked for 0 days 16 hr and 0 min (should be days/weeks)
    TPD[V] = 5.015V (min 0.9V)

    ISS:
    The diffracted power is around 2.2%
    Last saturation event was 0 days 16 hours and 1 minutes ago (should be days/weeks)


    Possible Issues:

Displaying report 1-1 of 1.