Displaying report 1-1 of 1.
Reports until 00:13, Wednesday 11 September 2019
H1 General
yannick.lecoeuche@LIGO.ORG - posted 00:13, Wednesday 11 September 2019 (51874)
Shift Summary - Evening

 

TITLE: 09/10 Eve Shift 23:00 – 07:00 (16:00-00:00), all times posted in UTC

STATE of H1: Observing

INCOMING OPERATOR: Corey

SHIFT SUMMARY: Sudden lockloss with SR2 saturation. Went into initial alignment after not being able to lock PRMI, but MICH_BRIGHT didn’t seem to work that well so I did MICH_DARK_LOCKED alignment and redid SRC_ALIGN. After that I lost lock from CARM_TO_TR, and then managed to reach NLN.

LOG:

23:00 (16:00) Start of shift

23:28 (16:28) Kyle back from MX

01:00 (18:00) Ethan to Optics Lab

01:19 (18:19) Ethan out of Optics Lab

04:33 (21:33) Lockloss with no warning. Alarm handler said SR2 saturated.

04:51 (21:51) Trouble locking PRMI, going to initial alignment

05:07 (22:07) Initial alignment complete, re-locking (issues with mich bright)

05:48 (22:48) Lockloss from CARM_TO_TR

06:47 (23:47) At NLN, going into Observing

07:00 (00:00) End of shift

Displaying report 1-1 of 1.