h1cdsrfm is back up and running, long range dolphin is working except from EY to CS. I suspect a left over from July's problems, I'm working on this.
Also h1edc appears to have lost connection to 90 digital video channels?
Configuration looks fine. Back on 24th July 2019 we moved the long range dolphin EY switch port from 6 to 4 (port 6 was wedged), and I had changed the configuration accordingly. I just did a switch port enable for h1cdsrfm and it correctly enabled port 4 at EY.
Problems with EY Port 4 now?
h1boot1 etc # ./dolphin_ix_remote_enable_bootserver.sh h1cdsrfm
--enable
Enabling switch_no 10.101.0.90, port 5
Complete - /opt/DIS/var/smbus: Read-only file system
not a valid lock (fd=-1)
csr write addr=0x00014050, val=0x20820080 (with ret=0)
--enable
Enabling switch_no 10.101.0.93, port 7
Complete - csr write addr=0x00004050, val=0x20820080 (with ret=0)
--enable
Enabling switch_no 10.101.0.94, port 4
Complete - csr write addr=0x00008050, val=0x20820080 (with ret=0)
IPC MEDM sans EY->CS traffic