Reports until 06:21, Wednesday 11 September 2019
H1 CDS
david.barker@LIGO.ORG - posted 06:21, Wednesday 11 September 2019 - last comment - 07:38, Wednesday 11 September 2019(51898)
CDS is back up and running

Richard, Corey, Dave:

I disabled Dolphin EY port 4, Richard moved the RFM cable from port 4 to port 5 and we now have IPC traffic in both directions to EY. 

CDS overview is now all GREEN, looks like our recovery from h1boot1 crash is complete.

Images attached to this report
Comments related to this report
david.barker@LIGO.ORG - 06:22, Wednesday 11 September 2019 (51899)
Images attached to this comment
david.barker@LIGO.ORG - 06:29, Wednesday 11 September 2019 (51900)

I've modified the configuration file on h1boot1 (/diskless/root/etc/ixnodetab) to move h1cdsrfm Y0 to port 5.

h1susey    Y0  1

h1seiey    Y0  2

h1iscey    Y0  3

h1cdsrfm   Y0  5 002353

keith.thorne@LIGO.ORG - 07:38, Wednesday 11 September 2019 (51902)
The end-station problem is horribly like the problems we had at LLO last week replacing l1iscex - see LLO log 48295.  Again one port on the switch would not respond to port enable/disable commands.  As you did, we just moved it to another port.  We tried using the 'RESET' command on the web interface (suggested by the vendor previously), but that was insufficient.  It may requires a power cycle after the reset, but it is unclear.  I am elevating this issue with the vendor to get a resolution.