mark.barton@LIGO.ORG - posted 15:08, Friday 18 January 2013 - last comment - 14:50, Monday 21 January 2013(5163)
PRM and PR3 TFs
Mark B.

Deepak centered the OSEMs on PRM and PR3 so I rechecked settings and got the damping working. I noticed that the WD thresholds had not been set nor the filters enabled, so I fixed that and redid the safe.snap files.

Damped and undamped TFs for both will commence shortly and continue through the night. The respective Measurement Status indicators will light when a measurement is in progress.
Comments related to this report
mark.barton@LIGO.ORG - 14:50, Monday 21 January 2013 (5191)
Mark B.

The PRM TFs went fine:
Undamped: 2013-01-18-1042586592_H1SUSPRM_M1_0p01to50Hz_tf.mat
Damped: 2013-01-18-1042606494_H1SUSPRM_M1_0p01to50Hz_tf.mat

Plots look good.

The PR3 TFs aborted due to a dumb typo of mine in the top-level script and were restarted at 11:01 am on 1/21.