Reports until 09:01, Tuesday 17 September 2019
H1 IOO
cheryl.vorvick@LIGO.ORG - posted 09:01, Tuesday 17 September 2019 - last comment - 15:01, Tuesday 17 September 2019(51988)
PRM parking offsets updated

The previous offsets for parking the REFL beam were allowing some of the beam back onto Calcite Wedge 2, as seen in the IO_FI_OUT analog camera.    Offsets are H1:SUS-PRM_M1_TEST_P_OFFSET and H1:SUS-PRM_M1_TEST_Y_OFFSET.  Pitch offset was+781, now +681, yaw offset was -5614, now -5914.  Accepted in SDF.

Images attached to this report
Comments related to this report
yannick.lecoeuche@LIGO.ORG - 13:59, Tuesday 17 September 2019 (52002)

Accepting sdf's in Observe.

Images attached to this comment
jenne.driggers@LIGO.ORG - 15:01, Tuesday 17 September 2019 (52003)

I don't remember of the top of my head what the calibration of these offsets to urad is, but we need to ensure that the reflected beam will still be hitting the dedicated beam dump on top of HAM2 when PRM is misaligned.