Displaying report 1-1 of 1.
Reports until 10:03, Tuesday 22 January 2013
H1 DAQ
david.barker@LIGO.ORG - posted 10:03, Tuesday 22 January 2013 (5199)
MSR Sataboy is down, no frames on h1fw1

The H1 DAQ SATABOY disk raid system in the MSR failed at 01:27 local time Sunday morning (the Sunday gremlin?). From that time onwards h1fw1 has not been able to write frames. We will leave the system in its broken state for LDAS to do some forensics. This is the system that was upgraded to Sol11 on Thursday, we are investigating if that had anything to do with the failure.