Reports until 12:29, Tuesday 17 September 2019
H1 TCS
thomas.shaffer@LIGO.ORG - posted 12:29, Tuesday 17 September 2019 - last comment - 17:26, Wednesday 18 September 2019(51996)
Swapped TCSY Chiller

WP8349

Betsy and I swapped the TCSY chiller with the rebuilt original chiller. This chiller was swapped back in January due to a leaky shaft seal. There was lots of corrosion in the pump, so we got a brand new pump and motor mounted and tested.

The hope with this chiller swap is that this chiller's temperature is a bit more stable and we won't have as many laser relocks that take us briefly out of observing (see alog 50789 for more info).

The laser recovered within an hour as usual, and temperatures and pressures all seem good. For the short time that we have been running with this current chiller, it looks good. Time will tell.

Current chiller: S/N127640801150617

Old chiller: S/N0110193301120813

-----

(Analog_1 is pressure in psi. Analog_2 I believe is actually temperature near or on the laser itself, not  pressure as the medm states.)

Attachment 1 - The current chiller stabilizing.

Attachment 2 - One day trend, showing the current values compared to the old chiller.

 

Images attached to this report
Comments related to this report
thomas.shaffer@LIGO.ORG - 17:26, Wednesday 18 September 2019 (52023)

A day later and things are looking a bit more stable than with the other chiller.