Displaying report 1-1 of 1.
Reports until 16:47, Sunday 22 September 2019
LHO General (SEI)
corey.gray@LIGO.ORG - posted 16:47, Sunday 22 September 2019 - last comment - 17:28, Sunday 22 September 2019(52068)
Transition to EVE Log

TITLE: 09/22 Eve Shift: 23:00-07:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 113Mpc
OUTGOING OPERATOR: Patrick
CURRENT ENVIRONMENT:
    SEI_CONF state: WINDY
    Wind: 27mph Gusts, 15mph 5min avg
    Primary useism: 0.05 μm/s
    Secondary useism: 0.14 μm/s

Winds have started picking up a little over the last 2hrs.  Other than that, microseism continues its downward trend to quiet levels.
QUICK SUMMARY:

H1 locked/observing for almost 10hrs.  All looking nice.

As I brought up SEI_CONF & SEISMON windows, I did notice that the SEI_CONF node ALL window has a non-True NOMINAL state (it's outer box for WINDY is orange, not the usual green).  Having trouble tracking down how long it's been "orange". 

Patrick noted that on the ISI_CONF medm, the BRSY has a status of a yellow "DAMPING" (vs a green "READY").

Comments related to this report
corey.gray@LIGO.ORG - 17:28, Sunday 22 September 2019 (52070)SEI

~0:16 Looks like SEI_CONF is good (& green).

It stopped DAMPING and returned to the normal READY state.

So BRSy was damping from 22:30 - 0:16.