Displaying report 1-1 of 1.
Reports until 00:53, Monday 23 September 2019
H1 General
thomas.shaffer@LIGO.ORG - posted 00:53, Monday 23 September 2019 - last comment - 02:29, Monday 23 September 2019(52073)
Lock Loss 0751 UTC

Had an EX saturation and then about 15 seconds later it lost lock.

Comments related to this report
thomas.shaffer@LIGO.ORG - 02:29, Monday 23 September 2019 (52076)

1253260325

SRC1_P, SRC2_P, and DHARD_Y seemed to drift away before everyone else. So SRM?

Images attached to this comment