Per ECR E1900176, FRS 13051, WP 8364, measured the effect of moving the IO high power beam dump hoses. The largest changes were seen at 420Hz, 480Hz, and 550Hz, where the coherance peaks at those frequencies, between the PSL periscope Y accelerometor and the IMC WFS signal WFS A Yaw measured anywhere between 0 and 0.6. Of course there was no one hose position that minimized alll of the peaks, but the changes, with changing the hose locations, were easily identified.
Hose positions tried:
It was clear that there were outside influences to the measurements, and I suspect first and foremost the temperature of the PSL, so the coherance at 550Hz was low when we started, and high when we left, and I believe the coherance will decrease as the PSL temperature returns to steady-state Scinence Mode.
Plots will be added later.
- Jason, Cheryl