23:28 Re-locking from EQ attempt -1 (my shift)
- Running INIT and DOWN did NOT re-align ITMs!
- Had to select ALIGN for both ITMs to get ALS flashing back
- Moved to PRMI to correct questionable alignment to deal with less than favorabel conditions
00:18 NLN
- 4 SDF diffs - They are with regards to radiation pressure- Jeff K and Evan H are investigating which action to take to get to Observing
00:36 H1 back to Observing