SDF Diffs: ASC Hard Loop Gains & ITM TRamps

Just made it back to NOMINAL LOW NOISE, and have  a few SDF Diffs.

1)  ASC Hard Loop Gains  (diff screenshot attached)

(Please see Jeff's specifics here.)

Evan was here, so I asked for his help.  Basically he:

Operators should be able to do this on their own, but the situation can be also be fixed by (1) touching up PSL alignment and/or changing Guardian script.

2) ITM TRamps (diff screenshot attached)

Keita and Matthew made changes to this during a Commissioning period today (REVERTED these).