Displaying report 1-1 of 1.
Reports until 18:12, Wednesday 02 October 2019
H1 SQZ (SQZ)
nutsinee.kijbunchoo@LIGO.ORG - posted 18:12, Wednesday 02 October 2019 - last comment - 18:19, Wednesday 02 October 2019(52263)
HAM6 Vent work: SQZ fiber swapped

Nutsinee Fabrice Sheila Gerardo Daniel

After the vent, the fiber transmission recovered,  back up to 6 mW (from about 3mW before the vent). The unit was de-installed and will be shipped back to MIT for diagnostic. The new unit (SN6) was installed.

Power measurements with old fiber after the vent:

Power measurement with new fiber:

-- Fabrice not happy. 5m fiber swapped for a new one. --

Power measurement with new in-air fiber:

-- Fabrice is less diapointed (transmission was better on the test bench) --

We left the laser on for the night, at lower power (~12mW input)  to monitor the health of the power transmission.

Comments related to this report
sheila.dwyer@LIGO.ORG - 18:19, Wednesday 02 October 2019 (52270)

Here are trends of the pressure in HAM6, the SHG launched power, the green fiber rejected polarization and the OPO reflection.  

During this time Daniel was adjusting the polarization into the fiber, so we need to look at the sum of the rejected polarization and the reflected power.  It seems that this recovery isn't happening slowly over the hours between the vent and when we first measured, but it is happening more quickly around the time that we first let light into the fiber (which was also around the time that we went to the chamber to make measurements).

Images attached to this comment
Displaying report 1-1 of 1.