Reports until 15:19, Thursday 03 October 2019
H1 CAL (CAL)
sudarshan.karki@LIGO.ORG - posted 15:19, Thursday 03 October 2019 - last comment - 10:05, Friday 04 October 2019(52287)
Processed High Frequency measurement from last few weeks of O3a

SudarshanK, JeffK, LilliS

Two additional sets of high frequency sweeps (2019-09-10 and 2019-09-22) have been  processed and included in the HDF5 file that was previously generated and describe in alog #52132

The resultant HDF5 file and the script used to generate it can be found here:

^trunk/Runs/O3/H1/Scripts/Uncertainty/process_allmeas_includingPCALXHFdata_writeGPRHDF5_model20190909-C.py
^trunk/Runs/O3/H1/Results/Uncertainty/O3_H1_C_GPR_20190909_nofsQcorr_fmin20Hz_lengthscaleZp5_withPCALXHFdata.hdf5

The plots are attached with this alog.

 

Non-image files attached to this report
Comments related to this report
ling.sun@LIGO.ORG - 10:05, Friday 04 October 2019 (52288)

Using the updated GPR results, the uncertainty improves at high freq. See plot.

Command line:

python3 RRNom.py --IFO=LHO --HDF5_A_MCMCresults=/ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/O3/H1/Results/Uncertainty/O3_H1_A_MCMC_20190404.hdf5 --HDF5_A_GPRresults=/ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/O3/H1/Results/Uncertainty/O3_H1_A_GPR_20190909_multi.hdf5 --HDF5_C_MCMCresults=/ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/O3/H1/Results/Uncertainty/O3_H1_C_MCMC_20190904_nomconfig_fmin20Hz_finaltrial.hdf5 --HDF5_C_GPRresults=/ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/O3/H1/Results/Uncertainty/O3_H1_C_GPR_20190909_nofsQcorr_fmin20Hz_lengthscaleZp5_withPCALXHFdata.hdf5 --modelPath=/ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/O3/H1/params/ --modelFilename=modelparams_H1_20190909 --IFOmodel=modelPars --outDir=/ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/O3/H1/Results/Uncertainty/ --plot1SigmaUncs --sampleNumber=1000 --seed=1234 --version=ref --gpsTime=1251687618 --saveSummaries

The comparison between the new results and the uncertainty without including these 2 new HF data sets are attached as the pdf.

The two data sets being compared are:

^trunk/Runs/O3/H1/Results/Uncertainty/2019-09-27_O3_LHO_GPSTime_1251687618_ref_RelativeResponseUncertainty_FinalResults.txt

^trunk/Runs/O3/H1/Results/Uncertainty/2019-10-03_O3_LHO_GPSTime_1251687618_ref_RelativeResponseUncertainty_FinalResults.txt

Images attached to this comment
Non-image files attached to this comment