HAM 6 Yawed Septum Viewport installed

C. Gray, G. Moreno, T. Sadecki, B. Weaver

Install of the new yawed septum viewport in HAM 6 went very smoothly today.  We utilized 2 of the aligment pins (3/8-16 silver plated screws with the heads lathed down to thread diameter) that Tyler made for us.  This made the installation much easier as we had something to take the weight of the 22 kg viewport assembly while installing the mounting flange screws.  The septum window accelerometer was reinstalled in the same location it was removed from.  First Contact was removed from the inner, HAM 5 side prior to installation, and the outer, HAM 6 side was removed in-chamber after installation and torquing.  The center of the viewport aperture was inspected and was deemed free from egregious amounts of particles.  

On a related note, this was the first time I had the chance to use the new modular stair system around the HEPIs and can attest that they work much better than the previous iterations of HAM chamber stairs.  

Photos to follow.

Comments related to this report
corey.gray@LIGO.ORG - 16:04, Monday 07 October 2019 (52331)SYS, VE
Attached are photos from new yaw-ed septum viewport install at HAM6 (names of pics gives brief description of image).
Images attached to this comment
stephen.appert@LIGO.ORG - 17:37, Monday 07 October 2019 (52337)

Is it in somebody's to-do list to add a notion of the alignment pin fixturing to the documentation? Seems like that fixture should be part of the final drawing package. Let me know if a hand is needed with that.

chandra.romel@LIGO.ORG - 18:52, Monday 07 October 2019 (52345)

The "alignment" pins were a last minute tool made to help support the weight of this ~ 50 lb piece of hardware. A design improvement would be to reduce the weight by perhaps making it out of aluminum. It is difficult to get two bodies in the chamber for this maneuver and diverted the time of one of our vacuum engineers a full day.

betsy.weaver@LIGO.ORG - 16:48, Wednesday 09 October 2019 (52377)

For the record,  this is the AS viewport assembly that was removed:

ASSY-D1101092-3 HQ Wedged 6 in Septum VP
  2-253V75--BULK-C30Q002 Dupont O-Ring #AS568-253 Viton 75, V75 FKM, Inside Diameter 5.359", Cross Section 0.139"
  D1003207-V1-00-C6Q002 High quality, 6in Viewport, Viewport Spacer
  D1101005-V1-12KWZ-S5-1363-S5-1364-0015 aLIGO, high quality, .75 deg wedged, 6" Viewport, AR-1064 nm Optic
  D1101115-V5-00-0007 High Quality, 6" Viewport CLAMP, wedged
  D1101117-V3-00-0006 aLIGO Septum Viewport FLANGE

 

And this is the viewport assembly that was installed earlier this week:

ASSY-D1900198-001 LHO Yawed, Septum Viewport Assy
  D070082-V1-00-0006 ELI Septum Window
  D1101117-V3-00-0022 aLIGO, Septum Viewport Flange
  D1900240-V3-00-0001 aLIGO, VE, HIGH QUALITY VP, WEDGE CLAMP
  D1900327-V1-00-0002 aLIGO, VE, HIGH QUALITY VP ASSY., YAW ADAPTER