Displaying report 1-1 of 1.
Reports until 22:10, Wednesday 23 January 2013
H1 ISC
lisa.barsotti@LIGO.ORG - posted 22:10, Wednesday 23 January 2013 - last comment - 12:10, Thursday 24 January 2013(5237)
IMC is locked again
All

The repaired LSC RFPD has been re-installed on IOT2, and we could relock the IMC easily. We measured the OLTF of the fast loop: we have a 60 kHz UGF and 40 degrees of phase margin (measured with the  730 kHz notch ). Details will follow. 
Comments related to this report
lisa.barsotti@LIGO.ORG - 12:10, Thursday 24 January 2013 (5244)
The first picture shows a comparison of the OLTF with and without the notch. At 60 kHz we lose 7 degrees of phase with the notch in.  The second picture shows where the notch box is, and the third picture shows the MEDM screens with the standard gain settings. 
Images attached to this comment
Displaying report 1-1 of 1.