Displaying report 1-1 of 1.
Reports until 09:39, Tuesday 15 October 2019
H1 SEI
chiara.difronzo@LIGO.ORG - posted 09:39, Tuesday 15 October 2019 - last comment - 16:35, Tuesday 21 April 2020(52477)
LSC AND CPS SIGNALS: H1OAF AND H1SEIPROC MODIFICATIONS + SCREENS

Chiara, Jenne, Jim.

Yesterday, Mon 14th Oct, we modified a number of models to prepare to try the control scheme outlined in T1900656. We hope to use differential CPS signals on corner station ISI's to improve low frequency cavity motion. This is very similar to the measurements Arnaud and Seb have been working on at LLO.

Now that we have modified, compiled and installed the models, we started to create screens: we need a filter bank matrix for CPS and one for LSC. The output of every row of a matrix will be added to the corresponding output of the other matrix, and the sum will be sent to the corresponding limiter. A draft of the CPS filter bank matrix, LSC filter bank matrix and signals to limiters are shown in screenshots 4,5,6.

Modified models are scheduled to re-start today.

 

Images attached to this report
Comments related to this report
arnaud.pele@LIGO.ORG - 16:35, Tuesday 21 April 2020 (55945)

For future reference this was an implementation of ECR E1900330

Displaying report 1-1 of 1.