ALSy Bad Green Mode Matching - Round 4

Keita, Dripta, Georgia

Today we continued investigating the poor mode matching of the ALS-Y green beam, following on from work eariler in the year. We took some new photos and used the wincam camera profiler to look at the beam. We haven't solved the problem but we noted that:

 

Next week we might monitor the profile of the reflected beam while adding offsets to the QPD servo, which will change the beam position on the transmon optics, to see if there is some clipping.

Images attached to this report
Comments related to this report
keita.kawabe@LIGO.ORG - 12:11, Sunday 20 October 2019 (52582)

1. Viewport beam spot position

1st and 2nd picture show the beam position on the viewport. In the first picture you can also see the two AR ghost beams hitting the inside of the duct material.

That the beam is close to the edge of the viewport will NOT affect the polarization but could affect the beam shape as the edge of the viewport is not really flat and could act as an irregular lens. We don't know how much the effect is at the current beam position, though.

(In the past, Pcal team found that excessive amount of aberration observed in ITM pictures taken with large aperture telescope (see e.g. the last page of https://alog.ligo-wa.caltech.edu/aLOG/uploads/35327_20170404172516_IrLowPower_reduced.pdf for example) is not observed in their tests outside of the vacuum chamber, and that it is mitigated/eliminated by simply limiting the input aperture of the telescope, which means that the viewport surface is not flat at the edge.)

2. In-chamber TMS optics spot position

See this one VID_20191018_170216.mp4 on G1902047 showing the primary (big mirror at the bottom) and a flat mirror above the primary. Centering on flat mirrors doesn't matter that much. Anyway, it may be a bit low on the primary but I don't call this bad.

3. Green Polarization

It's only a minor problem for capturing the beam shape of the return beam (and a minor problem for ALS in general), and the first picture of Georgia's entry is entirely valid, but it might be somewhat interesting to think about the cause of wrong polarization.

When we placed a HWP upstream of ALS-M11 in D1400241 to minimize the transmission of the incoming beam on ALS-M11 (i.e. wrong polarization), the brightness of the return beam (i.e. coming back from the chamber) transmitted through ALS-M11 was still much brighter than that of the wrong-polarization incoming beam (and it didn't change much when we rotated the HWP because ALS-M11 is a PBS and we're not changing the polarization of the beam going into the chamber, just the power).

That the return beam in wrong polarization is brighter than the input beam in the wrong pol cannot be explained by geometric rotation of the polarization axes alone. If it's just geometric rotation, what is sent in comes back with the exact same polarization because ETM is retroreflecting and the return beam exactly follows the incoming path, cancelling the rotation effect.

It could however be explained by a combination of geometric rotation and polarization-dependent optics in chamber. For example dichroic mirrors are spec'ed for green S but not P (see e.g. E1000669). Green BSs seem to be spec'ed for P and S (e.g. E1000870), but no test data is supplied for P. Even though the ALS periscope on the ISCTEY (and ISCTEX) is designed to elliminate the geometric rotation such that S pol on ICST stays S pol on TMS, it cannot be perfect.

Images attached to this comment
georgia.mansell@LIGO.ORG - 13:15, Monday 21 October 2019 (52596)

Attached are the pictures Dripta took of the transmon viewed from the camera viewport. There is a lot of scattered green light.

  • The large mirror with the well-centered spot is a flat mirror (TEL-FM1 in figure 2 of T0900385)
  • The small mirror with the bright spot above it is the telescope secondary (TEL-M2, -200mm ROC). It's hard to tell but perhaps this is not well centered.
  • The right viewport with the green spots around it is the viewport we inject the green ALS beam from
  • The final picture also shows some of the steering optcs and lenses on the transmon which steer the beam onto the QPDs.
Images attached to this comment
keita.kawabe@LIGO.ORG - 13:50, Monday 21 October 2019 (52597)

From alog 51458 we know that the 00 mode is only about 70% of the total power.

If we want to explain this using some kind of weird lensing on ISCTEY of on the viewport, the lensing needs to be large. Just to have some understanding of how large, here's a calculation of the effect of the elliptic lensing of the viewport.

I assumed that the lens is cylindrical so the mode shape is only altered in one direction, and plotted the mode overlap of the lensed beam and an ideal beam in power, not amplitude, as a function of the lens focal length.

To degrade the power coupling to 70% just by using a cylindrical lens, you need the focal length of about 14 meters. That's a huge effect, unlikely to come from high quality viewport D1101006/E1100267 as the transmission wavefront error is specified to be within lambda/10 for 633nm over the clear aperture of 5.2".

 

Images attached to this comment