IAS: D. Cook, J. Oberling
SUS: B. Weaver
After several rounds of adjustment, pitch is within spec on the ITMy. Everything is now ready for Hugh & Co. to install the HEPI actuators. The final pitch/yaw numbers are reported below.
-
Pitch: 61 µrad down
-
Target: 12.5 µrad up
-
Error: 73.5 µrad down
-
Tolerance: ±160.0 µrad
-
Yaw: 67 µrad CCW
-
Target: 0.0 µrad
-
Error: 67 µrad CCW
-