alignment and relocking progress

Varun, Sheila, Jenne, Dan B, Georgia

Arm Alignment:

Thinking about the observations from last night alignment work, it sounds as though the X arm camera is not a good reference for our alignment from before the vent.  To summarize observations after the alignment of the X arm to the camera reference yesterday:

This morning Varun and I moved ITMX back towards its alignment at the end of O3a, according to the sliders and oplev, and let the green WFS run to ETMX and TMSX, which ended up in more similar alignment to where they were in O3a, we moved PR3 back to where it was in O3a and this recovered the X transmission diode and the COMM beatnote.  Then we realigned the beamsplitter to get the DIFF beatnote and MICH fringes to look OK, we have COMM at -2dBm and Diff at -13dBm.  

Vertex alignment (AS_C centering):

Seismic things:

Carm offset reduction:

We had no issues with the TR_CARM or RF DARM handoffs, but lost lock a in the later CARM offset reduction stages.