multple beams on ISS Second Loop steering mirror, and the back of AOE1

The HAM2 East Door analog camera is looking at the steering mirror for the ISS Second Loop, and the back of AOE1 baffle.

In the past I've alogged that the ISS 2nd Loop steering mirror has multiple beams, alog 48801, images 6 and 8 from the left.

The first attachment show two images of the the ISS 2nd Loop steering mirror, AROM RH2, and the back of AOE1, one image with the illuminator on, so this image has both visible light and IR light (bottom), and one image with IR only (top), and in both images one can see multiple beams on the 2" steering mirror and the frame of AOE1.

The next two images show the approximate view of AROM RH2 and AOE1 from the East side of HAM2, at a much higher viewing angle than is possible with the current camera setup.

The last image shows AOE2.

AOE1 and AOE2 were originally inteded to have SiC baffle plates on both sides of the frame, however, at the time of install only 2 SiC plates were available, so the descision was to install the first plate for AOE1 and AOE2.

Created FRS 13760, and have added it to WHAM2 Issue Tracker FRS 5117.