Testing foton.py ZPK importing a susmodel

Vlad

Continuing from conclusion of previous aLOG.

It looked like foton.py is importing filters correctly with minimal error, and should be able to import data from a complete susmodel. Here I discuss issues that arose when I tried to do this.

Relevant gds svn subdirectories for source code to which I refer throughout:

I attempted to plot the zpk data of the O2 susmodel with Python:

I attempted to plot the zpk data  of the O2 susmodel with Matlab:

Issues I encountered with foton.py:

In summary two issues:

I did the same changes as I made in Python through Matlab, to see how different the TF looks when I remove the positive poles, and it is definitely not the same thing.

For the time being, one still needs to use quack to import the susmodels.