CDS Maintenance Summary, Tuesday 29th October 2019

NCAL fast channel

Timesh, Jeff, Dave:

h1calex was modified to add a NCAL_MASTER NCALX part. This reads adc0_24 as the H1:CAL-NCALX_ENCODER_VELOCITY_OUT_DQ fast channel. A DAQ restart was required.

SEI and SUS model changes

Jenne, Jim, Chiara, Dave:

The models h1susbs, h1susprm, h1sussrm, h1seiproc, h1isietmx and h1isietmy were restarted. A DAQ restart was required.

DAQ Restart

Dave

at 12:05 PDT I restarted the DAQ for the above model changes. There were no problems with the restart, h1nds1 did not encounter any of last week's problems.

 

Comments related to this report
david.barker@LIGO.ORG - 14:31, Tuesday 29 October 2019 (52772)

CDS maintenance part deux:

Installed latest BRS and Guardian INI files into H1EDC. Increased data rate of NCAL ROTATION_VELOCITY channel from 1024 to 4096 Hz. Restarted h1calex and DAQ.

david.barker@LIGO.ORG - 14:58, Tuesday 29 October 2019 (52776)

I have patched and restarted all the Debian9 nucs in the control room. When nuc21 came back online is found that h1pslcam1 was not responsive.

I verified that this camera cannot be pinged or accessed over the network. I'll leave the blank window on the nuc display as a reminder that we need to check this camera on the next visit to the PSL enclosure.

david.barker@LIGO.ORG - 16:24, Tuesday 29 October 2019 (52782)

Daniel found Beckhoff SDF for PLC4 was frozen, I restarted h1sysecatc1plc4sdf on h1ecatmon0.