H1 ISC (Lockloss, SUS)
daniel.brown@LIGO.ORG - posted 03:17, Thursday 31 October 2019 - last comment - 08:48, Thursday 31 October 2019(52823)
ASC for full IFO woes and ITMX PUM coil watchdog trip

We are having issues in engaging ASC for full IFO. CHARD yaw starts off about -12000 each time we get there and we have to bring it in manually. After manually zeroing it and engaging a few seconds later we lose lock. So we are doing an initial alignment.

This last lockloss we were having the UL PUM coil watchdog trip on ITMX, the other quadrants seem fine. The violin damping channel H1:SUS-ITMX_L2_DAMP_OUT_P_MON is ringing up and looks to be causing this issue. Georgia's suspects mode 12.

 

Images attached to this report
Comments related to this report
daniel.brown@LIGO.ORG - 03:42, Thursday 31 October 2019 (52824)

We skipped ENGAGE_RF_VIOLINS, it lasted a bit longer but we still lost lock still during engaging ASC, not sure why.

The "ESD X driver is off" warning keeps repeatedly flashing up around CARM offset reduction and beyond, which is putting us all on edge. 

We will leave it trying to lock, we're all going home.

thomas.shaffer@LIGO.ORG - 08:48, Thursday 31 October 2019 (52827)

I need to change the ESD test on DIAG_MAIN. I'll have a look at it shortly, but in the mean time note that it is only real if it stays up.