Displaying report 1-1 of 1.
Reports until 04:04, Friday 01 November 2019
H1 ISC (Lockloss)
daniel.brown@LIGO.ORG - posted 04:04, Friday 01 November 2019 - last comment - 04:32, Friday 01 November 2019(52865)
Relocking

Not sure why we lost lock around 01:20 PST, no one was poking the interferometer at the time.

Comments related to this report
georgia.mansell@LIGO.ORG - 04:32, Friday 01 November 2019 (52867)
  • The TR_Y offset also didn't get set correctly when we went through DOWN, I updated it by hand.
  • To minimise the SRC error signals in PREP_ASC_FOR_FULL_IFO for an alignment with good buildups, we changed:
    • SRC1_P offset from -5 to -3.5 (this gets switched off as we power up anyway)
    • AS_C pitch offset from 0 to -0.16
    • AS_C yaw offset from 0 to -0.06
    • This worked well for this one lock and hopefully don't mess up initial alignment or DRMI
  • We've updated the final SRCL offset added in LOWNOISE_LENGTH_CONTROL to 50 cnts
Displaying report 1-1 of 1.