SDF Cleanup:
- ALSY Fiber Lock Refcav Limiter - accepted diff presumably from Daniel's effort on Wed
- ALSX QPD Offsets - 10^-17 diff in values from Sat change
- IM1, 2, and 3 ALignment Offsets
- PI Mode Feedback and Bypass buttons, iWAVE Lines and other settings REVERTED - word on the street is that these are not actively used so we reverted, likely from Jenne/Gavin work earlier in the week and last week.
- ETMY ESD PI MASTER OUTPUT DRIVE ACCEPTED as OFF (0.00) - in direction from Sheila
- IFO was previously set to INJECT_KILL, Cheryl brought back to INJECT_SUCCESS
- Craig's SEI CPS DIFF ON/OFF script halted with it in the OFF state
OUT of NOMINAL SETTINGS/CONFIGURATIONS not to believed to effect range and to be worked next Tuesday:
- ETMY HWS SLED is ON - will turn off early next week (SDF SET accepted as "OFF" due to incorrect sign of on/off switch)
- Safety Scaffolding still erected all over HAM5 and 6
- Phase Camera still installed on ISCT1
- Ladder for camera work still propped against HAM2