Here I compiled several days worth of sqz/asqz measurements with the homodyne in one plot. Everytime I make a measurement I get slightly more and more loss infer from antisqueeze. This could be an indication that our crystal is slowly degrading. However, it is also possible that I have a large uncertainty in the nonlinear gain measurement so it's difficult to draw a solid conclusion from the data taken during the past few days. It is true though that we used to have a threshold power of 18mW. Something to keep an eye out for.

