The TFs ran largely without incident - only one case of failing to read from NDS, in the 0.01-0.4 band for L.
M0 undamped: ^/trunk/QUAD/H1/ITMY/SAGM0/Data/2013-01-29-1043539447_H1SUSITMY_M0_0p01to50Hz_tf.mat
R0 undamped: ^/trunk/QUAD/H1/ITMY/SAGR0/Data/2013-01-29-1043558145_H1SUSITMY_R0_0p01to50Hz_tf.mat
M0 L, P, Y and T, and all R0 plots are good. M0 V and R show anomalies that don't look like anything in the Coloring Book and may be a measurement artifact. There's a discontinuity at 0.4 Hz, as if the gain of some component had mysteriously increased between bands.