Displaying report 1-1 of 1.
Reports until 13:01, Wednesday 06 November 2019
H1 General
edmond.merilh@LIGO.ORG - posted 13:01, Wednesday 06 November 2019 (53050)
PSL Status Report - Weekly FAMIS# 11037

 Laser Status:
    Front End Power is 32.41W (should be around 30 W)
    70W Output Power is 70.1W
    Front End Watch is GREEN
    70W Watch is GREEN

    PMC:
    It has been locked 1 days, 1 hr 18 minutes (should be days/weeks)
    Reflected power = 11.43Watts
    Transmitted power = 52.63Watts
    PowerSum = 64.06Watts.

    FSS:
    It has been locked for 0 days 21 hr and 54 min (should be days/weeks)
    TPD[V] = 4.754V (min 0.9V)

    ISS:
    The diffracted power is around 2.5%
    Last saturation event was 0 days 23 hours and 25 minutes ago (should be days/weeks)


    Possible Issues:

Displaying report 1-1 of 1.