Reports until 14:10, Wednesday 06 November 2019
H1 AOS (DetChar)
joshua.smith@LIGO.ORG - posted 14:10, Wednesday 06 November 2019 - last comment - 09:51, Friday 08 November 2019(53052)
Lasso results for today's range drop

Following up on work by Beverly, I ran a short Lasso run on today's range drop. The run spans 2019-11-06 02:00-07:00. Clearly very highly correlated channels are as follows:

Channel "Pearson Coefficient"
0.9799929848627831 H1:SQZ-DCPD_SUM_RMS1_MON.mean
0.9725502574463882 H1:SQZ-DCPD_RATIO_1_MON.rms
0.9312747855964804 H1:SQZ-DCPD_SUM_RMS1_MON.rms

The full page output is at https://ldas-jobs.ligo-wa.caltech.edu/~jrsmith/detchar/O3b/lasso-Nov-6-2019-2/ (updated using the fancy new python 3 version)

Figures below show:
1) The range drop from the summary pages.
2) The range and scaled SQZ DCPD channel
3) A scatter plot of range vs SQZ values
4) The other channels that are duplicate of the SQZ winner

I think not much new from what Beverly reported so far. Happy to follow up with further inquiries. 

Images attached to this report
Comments related to this report
jeffrey.kissel@LIGO.ORG - 09:56, Thursday 07 November 2019 (53063)DetChar, ISC, OpsInfo, SQZ
@DetChar -- these channels contain DARM / DELTAL / h(t) in them. They're BLRMS monitor channels comparing the squeezer performance (SQZ; via the NULL stream [the "difference" between OMC DCPDA and B]) against the OMC's DCPD SUM (i.e. the gravitational wave detecting photodiodes, and the DARM loop error signal). 

The first band (i.e. what eventually forms H1:SQZ-DCPD_SUM_RMS1_MON, and then H1:SQZ-DCPD_RATIO_1_MON), is a tight band pass around 1640 Hz -- the frequency region simply chosen to be a region we believe to be "shot/quantum noise dominated with no features."

There are 4 of these BLRMS data streams, and they should probably just be considered "unsafe" as copies of the gravitational wave channels.


H1:SQZ-DCPD_NULL_BP_1_INMON  (**and other associated EPICs records on similar name, but with the standard filter module suffixes; OUTMON, EXCMON, OFFSET, etc.)
H1:SQZ-DCPD_NULL_BP_2_INMON   **
H1:SQZ-DCPD_NULL_BP_3_INMON  **
H1:SQZ-DCPD_NULL_BP_4_INMON   **
H1:SQZ-DCPD_NULL_LP_1_INMON  **
H1:SQZ-DCPD_NULL_LP_2_INMON   **
H1:SQZ-DCPD_NULL_LP_3_INMON  **
H1:SQZ-DCPD_NULL_LP_4_INMON   **
H1:SQZ-DCPD_NULL_RMS1_MON  
H1:SQZ-DCPD_NULL_RMS2_MON   
H1:SQZ-DCPD_NULL_RMS3_MON 
H1:SQZ-DCPD_NULL_RMS4_MON  
H1:SQZ-DCPD_RATIO_1_DB_MON    
H1:SQZ-DCPD_RATIO_1_MON   
H1:SQZ-DCPD_RATIO_2_DB_MON
H1:SQZ-DCPD_RATIO_2_MON  
H1:SQZ-DCPD_RATIO_3_DB_MON 
H1:SQZ-DCPD_RATIO_3_MON  
H1:SQZ-DCPD_RATIO_4_DB_MON 
H1:SQZ-DCPD_RATIO_4_MON 
H1:SQZ-DCPD_SUM_BP_1_INMON **
H1:SQZ-DCPD_SUM_BP_2_INMON  **
H1:SQZ-DCPD_SUM_BP_3_INMON **
H1:SQZ-DCPD_SUM_BP_4_INMON  **
H1:SQZ-DCPD_SUM_LP_1_INMON **
H1:SQZ-DCPD_SUM_LP_2_INMON  **
H1:SQZ-DCPD_SUM_LP_3_INMON **
H1:SQZ-DCPD_SUM_LP_4_INMON  **
H1:SQZ-DCPD_SUM_RMS1_MON  
H1:SQZ-DCPD_SUM_RMS2_MON
H1:SQZ-DCPD_SUM_RMS3_MON
H1:SQZ-DCPD_SUM_RMS4_MON
Images attached to this comment
joshua.smith@LIGO.ORG - 09:51, Friday 08 November 2019 (53091)

Thank you very much Jeff. We have taken steps to remove all {IFO}:SQZ-DCPD_ channels for future lasso runs. However, it also occured to me that lasso was updated to by default not consider channels that don't change in the first ten minutes of its run. This is not a good way to catch changes in the middle of a segment. So I generated a full channel list by hand using: 

(ligo-summary-3.7) [joshua.smith@ldas-pcdev1 lasso-Nov-6-2019-4]$ gw_data_find -o H -t H1_T -u file -s 1257040818 -e 1257040918 -n | xargs FrChannels | egrep -v "OAF-RANGE|CDS-SENSEMON|CAL-CS_DARM|SQZ-DCPD_|SUS-*TM*MODE*" | egrep ".mean|.rms" | cut -d\  -f1 > chans.txt

and ran lasso on this much longer channel list. 

(ligo-summary-3.7) [joshua.smith@ldas-pcdev1 lasso-Nov-6-2019-4]$ nohup gwdetchar-lasso-correlation -i H1 -f chans.txt -T minute -a 0.2 -O 2.5 -J 16 -j 16 1257040818 1257058818 &

The results are here: https://ldas-jobs.ligo-wa.caltech.edu/~jrsmith/detchar/O3b/lasso-Nov-6-2019-4/ 

Conclusion: This points to H1:ISC-RF_C_SQZAOM200M_OUTPUTMON as the most highly correlated. But also has a list of channels highly correlated to that one, which I've pasted below. I am posting this hastily, as I have to run, so I am sorry, again I have not investigated these channels as a follow up yet, but I thought it could be helpful for commissioners to see the updated list. 

Channel

Pearson Coefficient

-0.9999996566205920

H1:ISC-RF_C_SQZAOM200M_OUTPUTMON.mean

-0.9330572847583630

H1:OMC-LSC_I_OUT_DQ.rms

0.8875620058071610

H1:ASC-OMCR_B_PIT_OUT_DQ.mean

0.887557437214179

H1:ASC-OMCR_B_MTRX_P_OUTMON.mean

0.8875548329386750

H1:ASC-OMCR_B_PIT_OUT16.mean

0.8875269357613680

H1:ASC-OMCR_B_PIT_INMON.mean

0.8875269357613680

H1:ASC-OMCR_B_PIT_OUTPUT.mean

-0.8867419443426080

H1:OMC-ASC_Y2_X_SIN_OUT16.rms

-0.8818601017037520

H1:SYS-TIMING_C_FO_A_PORT_5_SLAVE_VCXOCTRL.mean

-0.8818600988445600

H1:SYS-TIMING_C_FO_A_PORT_5_SLAVE_VCXOCTRL.rms

-0.8750126151025700

H1:OMC-ASC_P1_X_COS_OUT16.rms

-0.8673301041530260

H1:OMC-ASC_P2_X_SIN_OUT16.rms

-0.8642192268464130

H1:ISI-BS_ST2_BLND_RZ_GS13_CUR_IN1_DQ.rms

-0.8627117825481380

H1:OMC-ASC_Y2_X_COS_OUT16.rms

-0.861022683603709

H1:PEM-C_SUP_RACK1_TEMPERATURE.rms

-0.8610220968306960

H1:PEM-C_SUP_RACK1_TEMPERATURE.mean

0.858408671078947

H1:IOP-ASC0_ADC_DT_OUT16.mean

0.8573914259079220

H1:IOP-ASC0_ADC_DT_OUT16.rms

-0.8571425309954690

H1:HPI-ITMY_BLRMS_VP_30M.rms

-0.8571423785897070

H1:HPI-ITMY_BLRMS_VP_30M.mean

-0.856700860825061

H1:OMC-ASC_Y1_X_COS_OUT16.rms

-0.856420367475446

H1:HPI-ITMY_BLRMS_LOG_VP_30M.rms

-0.8564203318837560

H1:HPI-ITMY_BLRMS_LOG_VP_30M.mean

-0.8527525850009830

H1:IMC-TRANS_IN1_DQ.mean

-0.8527518540230320

H1:IMC-TRANS_OUT_DQ.mean

-0.8527496025226880

H1:IMC-TRANS_OUT_DQ.rms

-0.8527473701532360

H1:IMC-TRANS_OUT16.rms

-0.8527470948451950

H1:IMC-TRANS_OUT16.mean

-0.8527326142606620

H1:IMC-TRANS_IN1_DQ.rms

-0.8523469401317910

H1:OMC-ASC_P1_X_SIN_OUT16.rms

-0.850131863101939

H1:OMC-LSC_Q_OUTPUT.rms

-0.850131863101939

H1:OMC-LSC_Q_INMON.rms

Images attached to this comment