Reports until 12:40, Thursday 07 November 2019
H1 General
edmond.merilh@LIGO.ORG - posted 12:40, Thursday 07 November 2019 - last comment - 16:36, Thursday 07 November 2019(53069)
Lockloss and Recovery 01:08UTC 18:09

18:09 Lockloss

Re-lock attempt -1

18:11 ALSY needed aligning

18:23 FIND_IR starting

18:35 Lockloss - trying to play catch-up with diff slider

18:39 Re-lock attempt - 2

19:10 Initial Alignment

19:25 IA complete

19:27 Re-Lock attempt - 3

19:52 Lockloss @ LOWNOISE_ASC

19:53 Re-Lock attempt -4

20:06 lockloss

20:07 Re-Lock attempt- 5

20:37 NLN

Comments related to this report
thomas.shaffer@LIGO.ORG - 15:17, Thursday 07 November 2019 (53074)Lockloss

Lock loss 1257185391

A very fast lock loss. I didn't see anything in the ASC signals (1st attachment), then I noticed that the squeezer lost lock just before the rest of the IFO (2nd attachment). I'm not sure how to tell if the squeezer losing lock was a cause or effect though.

Anther oddity is the slight jitter in H1:SUS-ETMX_L3_MASTER_OUT channel just before the lock loss. It seems to have large amounts of drive almost .4 seconds before. Out of time time to track down from where.

Images attached to this comment
thomas.shaffer@LIGO.ORG - 16:36, Thursday 07 November 2019 (53077)

One more, I looked at H1:SQZ-LO_SERVO_CTRL_OUT_DQ and it loses it before the main IFO.

Images attached to this comment