I multiplied the FM10 "cal" filter in H1:LSC-REFL_A_RIN and H1:LSC-REFL_B_RIN by 2.616, bringing the gain from 0.1168 to 0.3055, at Nov 08 2019, 00:44:23 UTC.
I did this because during my last intensity injection, the REFL A/Input RIN and REFL B/Input RIN TFs were not unity, equaling ~ 0.382.
After a quick chat with Daniel, the RIN chan was calibrated using the IFO at 2W, before thermal changes and RF driver sliders were changed.
I recalibrated it such that REFL {A,B}/Input RIN = 1 at full IFO with 38.1 W requested, 33.5 W incident on the PRM.