TITLE: 11/10 Eve Shift: 00:00-08:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Lock Acquisition
INCOMING OPERATOR: Corey
SHIFT SUMMARY: mostly in Observe, two lock losses, for the second lockloss I handed off to Corey with both arms locked in green
LOG:
- Nov 10 00:28:37 Intention Bit: Commissioning
- Nov 10 00:29:46 ISC_LOCK state: LOCKING_ARMS_GREEN
- 00:44:57 started on Y arm
- moved ETMY YAW from -135.2 to -136.2
- moved TMSY YAW from -278.6 to -278.7
- Nov 10 00:52:46 ISC_LOCK state: LOCKING_ALS
- Nov 10 00:53:41 ISC_LOCK state: FIND_IR
- Nov 10 00:53:43 ISC_LOCK state: LOCKLOSS
- Nov 10 00:54:51 ISC_LOCK state: LOCKING_ARMS_GREEN
- Nov 10 00:56:54 ISC_LOCK state: FIND_IR
- Nov 10 00:57:34 ISC_LOCK state: LOCKLOSS
- Nov 10 00:58:42 ISC_LOCK state: LOCKING_ARMS_GREEN
- Nov 10 01:00:44 ISC_LOCK state: FIND_IR
- Nov 10 01:01:00 Chandra and guest, gentle fast walk through LVEA
- South, West, North bays only, exited to High Bay
- Nov 10 01:02:16 ISC_LOCK state: ACQUIRE_DRMI_1F
- Nov 10 01:07:17 ISC_LOCK state: ACQUIRE_PRMI
- Nov 10 01:10:02 ISC_LOCK state: PRMI_TO_DRMI_TRANSITION
- Nov 10 01:10:13 ISC_LOCK state: ACQUIRE_DRMI_1F
- Nov 10 01:12:34 ISC_LOCK state: DRMI_LOCKED_PREP_ASC
- Nov 10 01:13:14 ISC_LOCK state: TURN_ON_BS_STAGE2
- Nov 10 01:14:07 DRMI Unlocked
- Nov 10 01:14:10 ISC_LOCK state: DOWN
- Nov 10 01:15:22 ISC_LOCK state: LOCKING_ARMS_GREEN
- Nov 10 01:19:09 ISC_LOCK state: CHECK_IR
- Nov 10 01:19:27 ISC_LOCK state: ACQUIRE_DRMI_1F
- Nov 10 01:20:56 ISC_LOCK state: LOCKING_ARMS_GREEN
- Nov 10 01:24:40 ISC_LOCK state: CHECK_IR
- Nov 10 01:24:58 ISC_LOCK state: ACQUIRE_DRMI_1F
- Nov 10 01:30:13 ISC_LOCK state: DOWN
- Nov 10 01:31:19 ISC_LOCK state: LOCKING_ARMS_GREEN
- Nov 10 01:34:52 ISC_LOCK state: CHECK_IR
- Nov 10 01:35:10 ISC_LOCK state: ACQUIRE_DRMI_1F
- Nov 10 02:02:44 ISC_LOCK state: NOMINAL_LOW_NOISE
- Nov 10 02:04:39 Intention Bit: Observing
- Nov 10 02:28:11 Intention Bit: Commissioning
- cursor error filter clicked on, was off, but filter bank gain was zero, so no change to H1 state
- Nov 10 02:28:42 Intention Bit: Observing
- Nov 10 02:54 32 Chandra and guest driving back from MX
- Nov 10 07:26:14 Intention Bit: Commissioning
- Nov 10 07:26:09 DRMI Unlocked
- Nov 10 07:27:17 ISC_LOCK state: LOCKING_ARMS_GREEN
- Nov 10 07:44:05 ISC_LOCK state: DOWN
- X arm solidly locked in a bad mode, Y arm not locking in 0-0
- Nov 10 07:46:26 ISC_LOCK state: LOCKING_ARMS_GREEN
- moved ETMX PITCH from 66.07 to 66.1, ETMX YAW from -132.68 to -132.61
- moved TMSX PITCH from -83.05 to -84.1, TMSX YAW from -48.6 to -48.9
- moved ETMY PITCH from 125 to 123.2, ETMY YAW from -135.5 to -134
- moved TMSY PITCH from 89 to 88, TMSY YAW from -278.65 to -278.18
- Nov 10 07:56:53 ISC_LOCK state: CHECK_IR
- Nov 10 07:57:11 ISC_LOCK state: ACQUIRE_DRMI_1F
- handed off to Corey