At GPS = 1043567822;
Common Mode Board: common gain = 20 db, compensation and 1st common boost on, fast gain = -2 db.
- MC2_M3_LOCK_L filters: gain -1000, FM5 (150:4) and FM8 (CLP100) enabled, limt to 400k.
- MC2_M2_LOCK_L filters: gain = 0.03, FM1 (0.01:0.1), FM2 (0.03:1), FM3 (Stab8:2), FM4 (300:1) and FM10 (ELF80) enabled, limit to 300k.