Leaving the IMC locked for the night

At GPS = 1043567822;

Common Mode Board: common gain = 20 db, compensation and 1st common boost on, fast gain = -2 db.

- MC2_M3_LOCK_L filters: gain -1000, FM5 (150:4) and FM8 (CLP100) enabled, limt to 400k.