The following files have been updated, with the contents listed below the file names. We plan to use these tomorrow to update the calculation of Pcal force coefficients in the Front End code.
/ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/O3/H1/Results/CALCS_FE/lho_xend_pcal_epics_created-20191111.txt
caput H1:CAL-PCALX_FORCE_COEFF_TX_PD_ADC_BG 9.035
caput H1:CAL-PCALX_FORCE_COEFF_RX_PD_ADC_BG 0.444
caput H1:CAL-PCALX_FORCE_COEFF_RHO_T 8.26228e3
caput H1:CAL-PCALX_FORCE_COEFF_RHO_R 1.06460e4
caput H1:CAL-PCALX_FORCE_COEFF_TX_OPT_EFF_CORR 1.00705
caput H1:CAL-PCALX_FORCE_COEFF_RX_OPT_EFF_CORR 0.99410
/ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/O3/H1/Results/CALCS_FE/lho_yend_pcal_epics_created-20191111.txt
caput H1:CAL-PCALY_FORCE_COEFF_TX_PD_ADC_BG 18.089
caput H1:CAL-PCALY_FORCE_COEFF_RX_PD_ADC_BG -0.707
caput H1:CAL-PCALY_FORCE_COEFF_RHO_T 7.11129e3
caput H1:CAL-PCALY_FORCE_COEFF_RHO_R 1.05763e4
caput H1:CAL-PCALY_FORCE_COEFF_TX_OPT_EFF_CORR 1.00626
caput H1:CAL-PCALY_FORCE_COEFF_RX_OPT_EFF_CORR 0.99493
/ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/O3/L1/Results/CALCS_FE/llo_xend_pcal_epics_created-20191111.txt
caput L1:CAL-PCALX_FORCE_COEFF_TX_PD_ADC_BG 3.943
caput L1:CAL-PCALX_FORCE_COEFF_RX_PD_ADC_BG -0.024
caput L1:CAL-PCALX_FORCE_COEFF_RHO_T 6.32501e3
caput LL:CAL-PCALX_FORCE_COEFF_RHO_R 1.01438e4
caput L1:CAL-PCALX_FORCE_COEFF_TX_OPT_EFF_CORR 1.00826
caput HL:CAL-PCALX_FORCE_COEFF_RX_OPT_EFF_CORR 0.99487
/ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/O3/L1/Results/CALCS_FE/llo_yend_pcal_epics_created-20191111.txt
caput L1:CAL-PCALY_FORCE_COEFF_TX_PD_ADC_BG 17.526
caput L1:CAL-PCALY_FORCE_COEFF_RX_PD_ADC_BG 1.872
caput L1:CAL-PCALY_FORCE_COEFF_RHO_T 6.59876e3
caput LL:CAL-PCALY_FORCE_COEFF_RHO_R 1.03193e4
caput L1:CAL-PCALY_FORCE_COEFF_TX_OPT_EFF_CORR 1.00547
caput HL:CAL-PCALY_FORCE_COEFF_RX_OPT_EFF_CORR 0.99461