5:26UTC H1 to Commissioning
5:48UTC H1 back to Observing
I had a look at the Guardian state when the damping was applied. It looks like it went from DAMPING_ON_SIMPLE (-13) to TURN_OFF_DAMPING_ALL state (30). The right way is to go from DAMPING_ON_SIMPLE (-13) to IDLE (-15) state and then to Damping_ON_DC (-11). This way Guardian is able to recollect the current status (else the information might be lost).