Operators have been running into a situation where the ALS IR serach is very sensitive to the dark offsets in the transmon QPDs being wrong. We (Jenne, Betsy and I) discussed raising the threhsold that is used in the fine_tune_IR states (for both comm and diff) I've reset the threshold in ISC_gen_states so that IR fine tune only happens when we have a normalized transmission above 0.1 (10% of on resonance transmission). Previously the threshold was 0.02
I've loaded both ALS_COMM and DIFF guardians, we will see if this helps us avoid operators needing to reset dark offsets in FIND_IR