Reports until 11:40, Wednesday 13 November 2019
H1 General
jeffrey.bartlett@LIGO.ORG - posted 11:40, Wednesday 13 November 2019 (53222)
Relocking after Lockloss
   Lost lock at 16:46 (08:46) At the time there was (1) incoming earthquake mag5.4 from El Salvador , SEI_CONF was in EARTHQUAKE state, (2) There was a bit of wind, and (3) There was activity with the wind fence installation. Not to say that these caused the lock loss. 

   Relocking Summary: 

   After 5 minutes ALS-Y had not locked. 
   Put ALS-Y Guardian into unlocked. Camilla moved Yaw from -135.3 to -135.5 and Pitch from 119.8 to 120.1. The signal jumped up to around 0.8. Switch back to OFFLOAD ALS-Y and WFS took it the rest of the way up. 

   At DRMI_1F, spot did not look so good. Started trying to lock DRMI at 17:05 (09:05). It dropped back to PRMI_LOCKING twice. DRMI_1F locked on the third try with 3 minutes left on the 20 minute countdown clock. 

   17:29 (09:29) - Lock loss at ENGAGE_ASC_FOR_FULL_IFO. 

The run up back to ENGAGE_ASC_FOR_FULL_IFO went smoothly with no operator intervention.

   17:44 (09:44) - Lock loss at ENGAGE_ASC_FOR_FULL_IFO. 

The run up back to ENGAGE_ASC_FOR_FULL_IFO went smoothly with no operator intervention.

   18:01 (10:01) - Lock loss at INCREASE_POWER

Jennie was working on Input Limitations ADS at the time

Relocking went well with Jennie and Camilla doing some hand tweaking (aLOG 53220)

   18:46 (10:46) Back to NLN and into Observing - No SDF Diffs to address.