Conor, Chiara.
There are two issues with the CAL_PRCL M1 Calibration:
1. The integrator doesn't reset, and causes numerical noise after some time. As such we will turn off the <0.01:0> filter module, and the calibration will be correct to approximately 10mHz, and then differ by this response. This removes the need for an AC-coupling filter, and we deleted it.
2. High-frequency noise (reported here: 53160), which we hope to solve by re-ordering the modules in the <H1CALCS_CS_SUM_PRCL_PRM_M1> filter bank.
The changes have been saved to the filter file, and we will load the coefficients tomorrow in maintenance.
So far, this seems to have fixed the issue with the PRCL calibration.