PSL spectra before and during IMC lock
I took spectra of the PSL before and after the IMC lock last night. I used the value of H1:IMC-REFL_DC_OUT shown in the attached plot to select times when the IMC was locked and unlocked. I assume that a low level in REFL indicates that the IMC is locked. I also made a PSL ODC plot for this period of time. The FSS loopstate bit in the PSL ODC goes bad at the time that the value of REFL goes high. I have attached four spectra for the PDA: two taken during the lock, which look similar to the spectra I took yesterday with the forest of high frequency lines, and two after the lock which look qualitatively quite different. The unlocked spectra bad as expected, probably due to the unlocked IMC putting junk into the PSL. However, the forest of lines is still there in the PSL spectrum when the IMC is locked. I will follow this up with Jan to understand what is going on.