Chiara, Jenne.
Today we took some measurements of PRCL with LSC_DIFF on and off for PRM M1. The CPS_DIFF was always ON. A couple of things to take note of:
LSCdiffFiltzpk = zpkgf(0,[0.05,0.05],1,0.005);
LSCboost=zpkgf([0.0878904+i.*0.0817023,0.0878904-i.*0.0817023],[0.0440496+i.*0.111623,0.0440496-i.*0.111623],1,1000);
LSCdiffFiltzpk = 2*LSCdiffFiltzpk*LSCboost;
The plot in attachment 1 shows the ratio between ON and OFF measured conditions (light blue) and expected conditions (black): probably we need a higher gain in the measurements.
Attachment 2 and 3 shows the crossovers between M1 and ISI, and M1 and M3, and the distribution filters. If you can notice something unusual in these plots around 0.7 Hz, the reason is that we did not change the M1 and M3 filters before applying LSC_DIFF: probbaly, in future, we will change those filters to roll off the M1 filter more steeply.
Last attachment shows the difference between PRCL open loop gain when we apply ISI offloading (red trace) with respect to the PRCL open loop gain withount ISI offloading (blue).
FUTURE WORK: