Displaying report 1-1 of 1.
Reports until 14:25, Monday 25 November 2019
H1 ISC
jenne.driggers@LIGO.ORG - posted 14:25, Monday 25 November 2019 - last comment - 16:34, Monday 25 November 2019(53481)
Iterative FF filters turned off

Around 22:24:00 UTC, during a commissioining period, I turned off the new iterative LSC feedforward filters.  We will see if the range is a teeny bit better with these turned off, or not.  If it is, then that implies that the requirements on the fits of the iterative filters are more stringent than I had thought, and will need to be done more carefully.

Comments related to this report
jenne.driggers@LIGO.ORG - 16:34, Monday 25 November 2019 (53485)

The range definitely went up a bit.  I'll look at either fitting these more carefully, or perhaps trying to fit the iteration-of-the-iteration data that I took after installing these filters last week.