FAMIS 11040
Laser Status:
Front End Power is 32.25W (should be around 30 W)
70W Output Power is 70.23W
Front End Watch is GREEN
70W Watch is GREEN
PMC:
It has been locked 20 days, 7 hr 20 minutes (should be days/weeks)
Reflected power = 11.61Watts
Transmitted power = 52.38Watts
PowerSum = 63.99Watts.
FSS:
It has been locked for 1 days 15 hr and 26 min (should be days/weeks)
TPD[V] = 4.785V (min 0.9V)
ISS:
The diffracted power is around 2.4%
Last saturation event was 1 days 15 hours and 25 minutes ago (should be days/weeks)
Possible Issues: None